“FOR A UNIQUE LIFESTYLE OPPORTUNITY”
No products in the cart.
Steel Liner Water Tanks
The Aqualine water tank is Bushmans range of large steel liner tanks designed and made for Australian conditions.
A key feature of the Aqualine galvanised or Colorbond steel tank range is that it is constructed on-site with galvanised or Colorbond steel walls and galvanised roof trusses with a poly liner to retain your water. This solution of a poly liner inside a steel tank (guaranteeing that your water never comes in direct contact with the steel structure) offers the best of both worlds when it comes to strength, durability and uncompromised water quality.
Designed to handle Australia’s toughest conditions these durable steel tanks deliver clean reliable water storage for your property, farm, or business.
Aqualine Poly Liner
The Aqualine Polytough® tank liner is strong and is manufactured to the highest standards which ensures it holds water over the long-term. Polytough® tank liners come in a range of materials including reinforced polypropylene, PVC, reinforced PVC and polyethylene.
Rural & Commercial Firefighting Tanks
Designed and manufactured to meet Australian firefighting standards (AS2304).
Steel Tank Features & Benefits
- Aqualine steel liner tank capacities range from 20,000L through to 360,000L – there is a size that will suit all applications
- Large water volumes means the cost per litre of storage can be lower
- They are erected on-site, so a large tank can be installed in places with limited access, including indoors
- 0.90mm thick Bluescope galvanised or Colorbond® walls
- 1.15mm thick Bluescope galvanised or Colorbond® bottom sheet of ASL150 and larger models
- 2 panel wall design for less seams
- Heavy duty circumference top support ring
- 40 X 40mm roof trusses for ASL20 to ASL80
- 50 X 50mm roof trusses for ASL100 and larger models
- Roof trusses are hot dipped galvanised providing long term rust protection
- Aqualine’s unique wall corrugation design for strength and support
- Galvanised or powder coated bolt covers
- Walls are bolted together with hi-tensile bolts providing excellent strength
- 100mm overflow
- 50mm outlet and ball valve
- Strainer and light guard
- High quality tank liner made to withstand Australia’s harsh conditions
- External removable ladder is standard
- Our galvanised and Colorbond® steel tanks do not need to use sacrificial anodes to reduce corrosion and maintain your warranty. No need for 5 yearly anode replacement.
Tank Colours
Bushmans offers a range of colours for the Aqualine tanks which will suit the most common colours used on buildings and fences.
Our most popular colours shown below are a guide only, for true colour representation, contact your Bushmans representative.





Aqualine tank designs have been validated by a professional engineer according to the relevant sections of the Building Code of Australia and the Australian Standard AS/NZS 1170.2
Rural Fire Tanks
In areas where there is any fire danger risk there are often local council regulations for the storage of adequate water for use by the fire brigade during building and bush fires.
Our Aqualine rural fire fighting tanks come with specific fittings enabling the local fire brigade to connect straight into the tank. These fittings are commonly called Stortz fittings or couplings. The benefit of this type of setup is that the local fire brigade will have local or on-site water available for firefighting, in the event of a fire. The brigade’s hoses and fittings connect straight into the fire fittings already installed on the tank.
The importance of adequate water on site cannot be understated. In a number of areas, local councils stipulate the amount of water that must be stored on site and immediately available for firefighting purposes if and when needed. The amount of water required on site will depend on the location, use, size and construction of buildings, land area and most importantly your local councils’ development control standards.
Water Tanks & Fire Storage Tanks
Fire water tanks can be dual purpose with a certain amount for water required to be quarantined for firefighting with the rest of the tank water available for domestic and livestock use. Bushmans has a fitting design that only allows a certain level of water to be drawn off for domestic use. For example, if the requirement is for 40,000 litres to be stored for firefighting and you have a 125,000 litre tank, then there is 85,000 litres available for other uses.
State Based Fittings & Regulations
In the different states there are different types of fittings that the fire brigades use so it is critically important that you select the right fitting for your state.
Victoria – CFA TTPI Coupling
South Australia – Stortz Tree or a Policy 14 Manifold
New South Wales – FRNSW Compatible Stortz Hose connector
Queensland a QLDFS Stortz or QRT male thread



Steel Liner Water Tanks Range
-

20,000 Litre Galvanised Steel Water Tank
POA Read more -

30,000 Litre Galvanised Steel Water Tank with Liner
POA Read more -

45,000 Litre Galvanised Steel Water Tank
POA Read more -

80,000 Litre Galvanised Steel Water Tank
POA Read more -

100,000 Litre Galvanised Steel Water Tank
POA Read more -

125,000 Litre Galvanised Steel Water Tank
POA Read more -

150,000 Litre Galvanised Steel Water Tank
POA Read more -

180,000 Litre Galvanised Steel Water Tank
POA Read more -

210,000 Litre Galvanised Steel Water Tank
POA Read more -

245,000 Litre Galvanised Steel Water Tank
POA Read more -

280,000 Litre Galvanised Steel Water Tank
POA Read more -

320,000 Litre Galvanised Steel Water Tank
POA Read more -

360,000 Litre Galvanised Steel Water Tank
POA Read more